08ps
for gaskets, washers, plugs, pipes, as well as parts subject to chemical and thermal treatment — sleeves, lugs, links.
for gaskets, washers, plugs, pipes, as well as parts subject to chemical and thermal treatment — sleeves, lugs, links.
Standard | Fe, % | Si, % | Mn, % | Cr, % | Cu, % | Ni, % | As, % | P, % | C, % | S, % |
---|---|---|---|---|---|---|---|---|---|---|
GOST 1050-88 | 98.215–99.55 | 0.05–0.17 | 0.35–0.65 | < 0.1 | < 0.3 | < 0.3 | < 0.08 | < 0.035 | 0.05–0.11 | < 0.04 |
Temperature, °C | $$E\cdot 10^{9}$$, $$MPa$$ | $$\alpha\cdot 10^{6}$$, $$K^{-1}$$ | $$\varkappa$$, $$\frac{W}{m\cdot K}$$ | $$\rho$$, $$\frac{kg}{m^3}$$ | $$c\cdot 10^{-3}$$, $$\frac{J}{kg\cdot K}$$ | $$R\cdot 10^{-6}$$, $$\Omega\cdot m$$ |
---|---|---|---|---|---|---|
20 | 203 | |||||
100 | 206 | 12.5 | 60 | 7846 | 0.482 | 0.178 |
200 | 183 | 13.4 | 56 | 7814 | 0.498 | 0.252 |
300 | 14 | 51 | 7781 | 0.514 | 0.341 | |
400 | 14.5 | 47 | 7745 | 0.533 | 0.448 | |
500 | 14.9 | 41 | 7708 | 0.555 | 0.575 | |
600 | 15.1 | 37 | 7668 | 0.584 | 0.725 | |
700 | 15.3 | 34 | 7628 | 0.626 | 0.898 | |
800 | 30 | 7598 | 0.695 | 1.073 | ||
900 | 27 | 7602 | 0.703 | 1.124 | ||
1000 | 0.695 |
Rolling | Standard | Size, mm | Tension | Classifiers | $$\sigma _{U}$$, $$MPa$$ | $$\sigma_{P}$$, $$MPa$$ | $$\epsilon_L$$, % | $$\psi$$, % | Treatment |
---|---|---|---|---|---|---|---|---|---|
Sheet termoobrabotki. | GOST 4041-71 | 4–8 | 270–410 | 32 | |||||
Trumpet | GOST 10705-80 | 314 | 196 | 25 | |||||
Rental calibrated. Hardened. | GOST 10702-78 | 370 | 8 | 60 | |||||
Rental calibrated. | GOST 10702-78 | 314–412 | 60 | Annealing | |||||
Band | 6–60 | 290 | 175 | 35 | 60 | Normalization |
Rolling | Standard | Classifiers | Value, HBW |
---|---|---|---|
Sheet termoobrabotki. | GOST 4041-71 | 1090 | |
The bar is hot rolled. | GOST 10702-78 | 1150 | |
Rental calibrated. | GOST 10702-78 | 1430 | |
Sheet annealed. | GOST 1577-93 | fat | 1310 |
USA | Germany |
---|---|
G10080 | 1.0337 (DC04GT) |
Standard | Description |
---|---|
GOST 1050-88 |
Parameter | Units of measurement | Description |
---|---|---|
$$E\cdot 10^{9}$$ | $$MPa$$ | Elastic modulus |
$$\alpha\cdot 10^{6}$$ | $$K^{-1}$$ | Coefficient of thermal (linear) expansion (range 20°C–T) |
$$\varkappa$$ | $$\frac{W}{m\cdot K}$$ | Coefficient of thermal conductivity (the heat capacity of the material) |
$$\rho$$ | $$\frac{kg}{m^3}$$ | The density of the material |
$$c\cdot 10^{-3}$$ | $$\frac{J}{kg\cdot K}$$ | The specific heat of the material (range 20°C–T) |
$$R\cdot 10^{-6}$$ | $$\Omega\cdot m$$ | Electrical resistivity |
Parameter | Units of measurement | Description |
---|---|---|
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |