30HN3M2FA (30HN3M2F)
steam turbine drives.
steam turbine drives.
Standard | Fe, % | Si, % | Mn, % | Cr, % | Cu, % | Ni, % | V, % | P, % | C, % | S, % | Mo, % |
---|---|---|---|---|---|---|---|---|---|---|---|
Standard | Fe, % | Si, % | Mn, % | Cr, % | Cu, % | Ni, % | V, % | P, % | C, % | S, % | Mo, % |
TU 108.1028-81 | 92.463–94.84 | < 0.37 | 0.2–0.5 | 1.2–1.7 | < 0.25 | 3–3.5 | 0.1–0.2 | < 0.025 | 0.26–0.32 | < 0.022 | 0.4–0.65 |
Standard | Description |
---|---|
Standard | Description |
TU 108.1028-81 |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
\sigma _{U} | MPa | Ultimate tensile strength |
\sigma_{P} | MPa | Proportionality limit |
\epsilon_L | % | Elongation at break (longitudinal) |
\psi | % | Reduction in cross section on fracture |
KCU\cdot 10^{3} | \frac{J}{m^2} | Impact toughness |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |