36H2N2MFA (36XH1MFA)
For large critical parts discs, mounting screws, etc. D.
For large critical parts discs, mounting screws, etc. D.
Standard | Fe, % | Si, % | Mn, % | Cr, % | Cu, % | Ni, % | V, % | P, % | C, % | S, % | Mo, % |
---|---|---|---|---|---|---|---|---|---|---|---|
GOST 4543-71 | 94.4–96.25 | 0.17–0.37 | 0.25–0.5 | 1.3–1.7 | < 0.3 | 1.3–1.7 | 0.1–0.18 | < 0.025 | 0.33–0.4 | < 0.025 | 0.3–0.4 |
Temperature, °C | $$E\cdot 10^{9}$$, $$MPa$$ | $$\alpha\cdot 10^{6}$$, $$K^{-1}$$ | $$\varkappa$$, $$\frac{W}{m\cdot K}$$ | $$c\cdot 10^{-3}$$, $$\frac{J}{kg\cdot K}$$ | $$R\cdot 10^{-6}$$, $$\Omega\cdot m$$ |
---|---|---|---|---|---|
20 | 212 | 36 | 0.278 | ||
100 | 204 | 12.5 | 36 | 0.496 | 0.335 |
200 | 198 | 12.8 | 35 | 0.508 | 0.432 |
300 | 186 | 13.3 | 35 | 0.525 | 0.517 |
400 | 173 | 13.5 | 34 | 0.538 | 0.613 |
500 | 166 | 14 | 33 | 0.567 | 0.72 |
600 | 156 | 14.3 | 31 | 0.601 | 0.825 |
700 | 139 | 14.5 | 30 | 0.672 | 0.94 |
800 | 127 | 11 | 29 | 0.697 |
Rolling | Standard | Size, mm | Tension | Classifiers | $$\sigma _{U}$$, $$MPa$$ | $$\sigma_{P}$$, $$MPa$$ | $$\epsilon_L$$, % | $$\psi$$, % | $$KCU\cdot 10^{3}$$, $$\frac{J}{m^2}$$ | Treatment |
---|---|---|---|---|---|---|---|---|---|---|
Rod | GOST 4543-71 | 25 | 1180 | 1080 | 12 | 50 | 780 | Hardening and tempering |
Rolling | Standard | Classifiers | Value, HBW |
---|---|---|---|
Alloy | GOST 4543-71 | annealing | 269 |
USA | Germany |
---|---|
4340 | 1.6582 (34CrNiMo6) |
Standard | Description |
---|---|
GOST 4543-71 |
Parameter | Units of measurement | Description |
---|---|---|
$$E\cdot 10^{9}$$ | $$MPa$$ | Elastic modulus |
$$\alpha\cdot 10^{6}$$ | $$K^{-1}$$ | Coefficient of thermal (linear) expansion (range 20°C–T) |
$$\varkappa$$ | $$\frac{W}{m\cdot K}$$ | Coefficient of thermal conductivity (the heat capacity of the material) |
$$c\cdot 10^{-3}$$ | $$\frac{J}{kg\cdot K}$$ | The specific heat of the material (range 20°C–T) |
$$R\cdot 10^{-6}$$ | $$\Omega\cdot m$$ | Electrical resistivity |
Parameter | Units of measurement | Description |
---|---|---|
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |