Structural steel alloyed 30X23H7SL in castings
No foreign analogues
Used in the manufacture of shaped castings for high-temperature equipment of oil refining and petrochemical industries
No foreign analogues
Used in the manufacture of shaped castings for high-temperature equipment of oil refining and petrochemical industries
Standard | Fe, % | Si, % | Mn, % | Cr, % | Cu, % | Ni, % | C, % | Mo, % | ET, % |
---|---|---|---|---|---|---|---|---|---|
Standard | Fe, % | Si, % | Mn, % | Cr, % | Cu, % | Ni, % | C, % | Mo, % | ET, % |
TU 4112-161-00220302-2011 | 63.63–71.8 | 0.5–1.2 | 0.5–1 | 21–25 | < 0.3 | 6–8 | 0.2–0.3 | < 0.5 | < 0.07 |
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{Y}, MPa | d5, % | Treatment |
---|---|---|---|---|---|---|---|---|
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{Y}, MPa | d5, % | Treatment |
Trumpet | TU 4112-161-00220302-2011 | > 539 | > 245 | > 12 |
Rolling | Standard | Classifiers | Value, HRC |
---|---|---|---|
Rolling | Standard | Classifiers | Value, HRC |
Trumpet | TU 4112-161-00220302-2011 | 30–32 |
Standard | Температура, °C |
---|---|
Standard | Температура, °C |
TU 4112-161-00220302-2011 | < 500 |
Standard | Description |
---|---|
Standard | Description |
TU 4112-161-00220302-2011 | TU 4112-161-00220302-2011 |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
E\cdot 10^{9} | MPa | Elastic modulus |
\alpha\cdot 10^{6} | K^{-1} | Coefficient of thermal (linear) expansion (range 20°C–T) |
\varkappa | \frac{W}{m\cdot K} | Coefficient of thermal conductivity (the heat capacity of the material) |
\rho | \frac{kg}{m^3} | The density of the material |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |