03N12H5M3TYUL
highly loaded parts critical applications with a wall thickness up to 200 mm
highly loaded parts critical applications with a wall thickness up to 200 mm
Standard | Fe, % | Si, % | Mn, % | Cr, % | Ti, % | Ni, % | Al, % | P, % | C, % | S, % | Mo, % |
---|---|---|---|---|---|---|---|---|---|---|---|
Standard | Fe, % | Si, % | Mn, % | Cr, % | Ti, % | Ni, % | Al, % | P, % | C, % | S, % | Mo, % |
GOST 977-88 | 77.68–80.04 | < 0.2 | < 0.2 | 4.5–5 | 0.7–0.9 | 12–12.5 | 0.25–0.45 | < 0.015 | 0.01–0.04 | < 0.015 | 2.5–3 |
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{P}, MPa | \epsilon_L, % | \psi, % | KCU\cdot 10^{3}, \frac{J}{m^2} | Treatment |
---|---|---|---|---|---|---|---|---|---|---|
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{P}, MPa | \epsilon_L, % | \psi, % | KCU\cdot 10^{3}, \frac{J}{m^2} | Treatment |
Castings | GOST 977-88 | 1472 | 1422 | 8 | 35 | 294 |
Standard | Description |
---|---|
Standard | Description |
GOST 977-88 |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
\sigma _{U} | MPa | Ultimate tensile strength |
\sigma_{P} | MPa | Proportionality limit |
\epsilon_L | % | Elongation at break (longitudinal) |
\psi | % | Reduction in cross section on fracture |
KCU\cdot 10^{3} | \frac{J}{m^2} | Impact toughness |