14G2AFD
Manganese-vanadium alloyed steel with nitrogen and copper; According to GOST 27772−88 corresponds to steel for building structures S390D
Steel structures of bridges
Manganese-vanadium alloyed steel with nitrogen and copper; According to GOST 27772−88 corresponds to steel for building structures S390D
Steel structures of bridges
Standard | Fe, % | Si, % | Mn, % | Cr, % | Cu, % | Ni, % | V, % | As, % | P, % | C, % | S, % | N, % |
---|---|---|---|---|---|---|---|---|---|---|---|---|
GOST 19281-89 | 96.32–98.145 | 0.3–0.6 | 1.2–1.6 | < 0.4 | 0.15–0.3 | < 0.3 | 0.07–0.12 | < 0.08 | < 0.035 | 0.12–0.18 | < 0.04 | 0.015–0.025 |
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{P}, MPa | \epsilon_L, % | Treatment |
---|---|---|---|---|---|---|---|---|
Sheet | GOST 19282-73 | 5–9 | 550 | 400 | 20 | |||
Sheet | GOST 19281-2014 | < 50 | 510 | 390 | 19 |
Standard | Description |
---|---|
GOST 19281-89 |
Parameter | Units of measurement | Description |
---|---|---|
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |