20832
Weldability without restrictions.
for use in magnetic circuits of electric devices and instruments
Classification
Country |
Section |
Category |
CIS, Russia, Ukraine |
Electrical steel |
Unalloyed electrical steel |
Chemical composition
Standard |
Fe, % |
Si, % |
Mn, % |
C, % |
GOST 3836-83 |
> 99.36 |
< 0.3 |
< 0.3 |
< 0.04 |
Information on suppliers
Magnetic properties
Rolling |
Dimensions, $$mm$$ |
$$H_c$$, $$A/m$$ |
$$\mu_{max}$$, $$MH/m$$ |
$$B_{500}$$, $$T$$ |
$$B_{1000}$$, $$T$$ |
$$B_{2500}$$, $$T$$ |
$$B_{5000}$$, $$T$$ |
$$B_{10000}$$, $$T$$ |
$$B_{30000}$$, $$T$$ |
Sheet |
0.7–3.9 |
32 |
6.3 |
1.38 |
1.5 |
1.62 |
1.71 |
1.81 |
2.05 |
Technological Properties
Standards
Description of chemical elements
Element |
Units of measurement |
Description |
Fe |
% |
Iron |
Si |
% |
Silicon |
Mn |
% |
Manganese |
C |
% |
Carbon |
Description of magnetic properties
Parameter |
Units of measurement |
Description |
Dimensions |
$$mm$$ |
|
$$H_c$$ |
$$A/m$$ |
Magnetic coercivity (not more) |
$$\mu_{max}$$ |
$$MH/m$$ |
Magnetic permeability (not more) |
$$B_{500}$$ |
$$T$$ |
Magnetic induction (not less) in a magnetic field while magnetic field strength is 500 A/m |
$$B_{1000}$$ |
$$T$$ |
Magnetic induction (not less) in a magnetic field while magnetic field strength is 1000 A/m |
$$B_{2500}$$ |
$$T$$ |
Magnetic induction (not less) in a magnetic field while magnetic field strength is 2500 A/m |
$$B_{5000}$$ |
$$T$$ |
Magnetic induction (not less) in a magnetic field while magnetic field strength is 5000 A/m |
$$B_{10000}$$ |
$$T$$ |
Magnetic induction (not less) in a magnetic field while magnetic field strength is 10000 A/m |
$$B_{30000}$$ |
$$T$$ |
Magnetic induction (not less) in a magnetic field while magnetic field strength is 30000 A/m |
Designation of types of weldability
Parameter |
Units of measurement |
Description |
no limits |
|
Welding is performed without heating and without subsequent heat treatment |
Boundedly welded |
|
Welding is possible with heating up to 100–120 °C and subsequent heat treatment |
Difficult to weld |
|
For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing |
Not applicable for welded structures |
|
|