20ps
without heat treatment or after normalization — pipes, fittings, plugs, bolts, flanges, housing units and other details of the boiling steel, operating from -20 to 425 ° C; after carburizing and cyanide — the details of which require high surface hardness and low core strength (axles, fasteners, toes, stars, etc.).
Classification
Country | Section | Category |
---|---|---|
CIS, Russia, Ukraine | Structural steel | Carbonaceous quality structural steel |
Chemical composition
Standard | Fe, % | Si, % | Mn, % | Cr, % | Cu, % | Ni, % | As, % | P, % | C, % | S, % |
---|---|---|---|---|---|---|---|---|---|---|
GOST 1050-88 | 97.935–99.43 | 0.05–0.17 | 0.35–0.65 | < 0.25 | < 0.3 | < 0.3 | < 0.08 | < 0.035 | 0.17–0.24 | < 0.04 |
Information on suppliers
Physical characteristics
Temperature, °C | $$E\cdot 10^{9}$$, $$MPa$$ | $$\alpha\cdot 10^{6}$$, $$K^{-1}$$ | $$\varkappa$$, $$\frac{W}{m\cdot K}$$ | $$\rho$$, $$\frac{kg}{m^3}$$ | $$c\cdot 10^{-3}$$, $$\frac{J}{kg\cdot K}$$ | $$R\cdot 10^{-6}$$, $$\Omega\cdot m$$ |
---|---|---|---|---|---|---|
20 | 212 | |||||
100 | 208 | 12.3 | 51 | 7834 | 0.486 | 0.219 |
200 | 203 | 13.1 | 49 | 7803 | 0.498 | 0.292 |
300 | 197 | 13.8 | 44 | 7770 | 0.514 | 0.381 |
400 | 189 | 14.3 | 43 | 7736 | 0.533 | 0.487 |
500 | 177 | 14.8 | 39 | 7699 | 0.555 | 0.601 |
600 | 163 | 15.1 | 36 | 7659 | 0.584 | 0.758 |
700 | 140 | 15.2 | 32 | 7617 | 0.636 | 0.925 |
800 | 26 | 7624 | 0.703 | 1.094 | ||
900 | 26 | 7600 | 0.703 | 1.135 | ||
1000 | 0.695 |
Mechanical properties at 20 °C
Rolling | Standard | Size, mm | Tension | Classifiers | $$\sigma _{U}$$, $$MPa$$ | $$\sigma_{P}$$, $$MPa$$ | $$\epsilon_L$$, % | $$\psi$$, % | Treatment |
---|---|---|---|---|---|---|---|---|---|
Sheet termoobrabotki. | GOST 4041-71 | 4–14 | 340–490 | 28 | |||||
Trumpet | GOST 10705-80 | 372 | 225 | 22 | |||||
Trumpet | GOST 10705-80 | 412 | 245 | 21 | |||||
The tape is annealed. | GOST 2284-79 | 310–540 | 18 | ||||||
The tape is hardcore. | GOST 2284-79 | 490–830 | |||||||
The steel is calibrated. | GOST 10702-78 | 490 | 7 | 45 | |||||
Band | GOST 1577-93 | 6–60 | 380 | 225 | 27 | 55 | Normalization |
Brinell hardness number
Rolling | Standard | Classifiers | Value, HBW |
---|---|---|---|
Sheet termoobrabotki. | GOST 4041-71 | 1270 | |
Sheet annealed. | GOST 1577-93 | fat | 1560 |
Technological Properties
Weldability | Flake Susceptibility | Propensity to temper brittleness |
---|---|---|
no limits | not sensitive | not inclined |
Critical point temperatures
Ac1, K | Ac3(Acm), K | Ar3(Arcm), K | Ar1, K |
---|---|---|---|
735 | 850 | 835 | 680 |
Analogues
USA |
---|
1020 |
Standards
Standard | Description |
---|---|
GOST 1050-88 |
Description of chemical elements
Element | Units of measurement | Description |
---|---|---|
Fe | % | Iron |
Si | % | Silicon |
Mn | % | Manganese |
Cr | % | Chrome |
Cu | % | Copper |
Ni | % | Nickel |
As | % | Arsenic |
P | % | Phosphorus |
C | % | Carbon |
S | % | Sulfur |
Description of physical characteristics
Parameter | Units of measurement | Description |
---|---|---|
$$E\cdot 10^{9}$$ | $$MPa$$ | Elastic modulus |
$$\alpha\cdot 10^{6}$$ | $$K^{-1}$$ | Coefficient of thermal (linear) expansion (range 20°C–T) |
$$\varkappa$$ | $$\frac{W}{m\cdot K}$$ | Coefficient of thermal conductivity (the heat capacity of the material) |
$$\rho$$ | $$\frac{kg}{m^3}$$ | The density of the material |
$$c\cdot 10^{-3}$$ | $$\frac{J}{kg\cdot K}$$ | The specific heat of the material (range 20°C–T) |
$$R\cdot 10^{-6}$$ | $$\Omega\cdot m$$ | Electrical resistivity |
Description of mechanical properties
Parameter | Units of measurement | Description |
---|---|---|
$$\sigma _{U}$$ | $$MPa$$ | Ultimate tensile strength |
$$\sigma_{P}$$ | $$MPa$$ | Proportionality limit |
$$\epsilon_L$$ | % | Elongation at break (longitudinal) |
$$\psi$$ | % | Reduction in cross section on fracture |
Designation of types of weldability
Parameter | Units of measurement | Description |
---|---|---|
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |
Description of temperatures of critical points
Parameter | Units of measurement | Description |
---|---|---|
Ac1 | K | |
Ac3(Acm) | K | |
Ar3(Arcm) | K | |
Ar1 | K |