3411
The chemical composition is not standardized.
cold rolled anisotropic tape designed for magnetic circuits of electrical machines and instruments
The chemical composition is not standardized.
cold rolled anisotropic tape designed for magnetic circuits of electrical machines and instruments
Standard | Fe, % | Si, % |
---|---|---|
GOST 21427.1-83 | 96.2–97.2 | 2.8–3.8 |
Standard | Description |
---|---|
GOST 21427.1-83 | GOST |
Parameter | Units of measurement | Description |
---|---|---|
Dimensions | $$mm$$ | |
$$P_{1.0/50}$$ | $$W/kg$$ | Specific magnetic losses (no more) while the magnetic induction is 1.0 T and frequency is 50 Hz |
$$P_{1.5/50}$$ | $$W/kg$$ | Specific magnetic losses (no more) while the magnetic induction is 1.5 T and frequency is 50 Hz |
$$B_{1000}$$ | $$T$$ | Magnetic induction (not less) in a magnetic field while magnetic field strength is 1000 A/m |
$$B_{2500}$$ | $$T$$ | Magnetic induction (not less) in a magnetic field while magnetic field strength is 2500 A/m |