Steel35G26X14M (Steel EP488)
No foreign analogues
Designed for the manufacture of forgings, turbine blades, fasteners, long-term working at temperatures up to 630 degrees C.
No foreign analogues
Designed for the manufacture of forgings, turbine blades, fasteners, long-term working at temperatures up to 630 degrees C.
Standard | Fe, % | Si, % | Mn, % | Cr, % | Ni, % | P, % | C, % | S, % | Mo, % |
---|---|---|---|---|---|---|---|---|---|
Standard | Fe, % | Si, % | Mn, % | Cr, % | Ni, % | P, % | C, % | S, % | Mo, % |
GOST 4543-71 | 54.495–61.32 | < 0.7 | 25–28 | 12.5–14.5 | < 0.6 | < 0.035 | 0.33–0.4 | < 0.02 | 0.85–1.25 |
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{Y}, MPa | d5, % | Treatment |
---|---|---|---|---|---|---|---|---|
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{Y}, MPa | d5, % | Treatment |
Round | GOST 5949-18 | 60 | Transverse | 650–700 | 290–300 | 35–40 |
Rolling | Standard | Classifiers | Value, HRC |
---|---|---|---|
Rolling | Standard | Classifiers | Value, HRC |
Rod | GOST 5949-18 | 180–220 |
Standard | Температура, °C |
---|---|
Standard | Температура, °C |
GOST 4543-71 | < 630 |
Standard | Description |
---|---|
Standard | Description |
GOST 4543-71 |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
E\cdot 10^{9} | MPa | Elastic modulus |
\varkappa | \frac{W}{m\cdot K} | Coefficient of thermal conductivity (the heat capacity of the material) |
\rho | \frac{kg}{m^3} | The density of the material |
R\cdot 10^{-6} | \Omega\cdot m | Electrical resistivity |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |