6G2AF

Weldability without restrictions. Flock sensitivity is not sensitive.

for welded structures

Classification

Country Section Category
CIS, Russia, Ukraine Structural steel Low alloy structural steel for welded structures

Chemical composition

Standard Fe, % Si, % Mn, % Cr, % Cu, % Ni, % V, % P, % C, % S, % N, %
GOST 2591-2006 96.26–98.165 0.3–0.6 1.3–1.7 < 0.4 < 0.3 < 0.3 0.08–0.14 < 0.035 0.14–0.2 < 0.04 0.015–0.025

Information on suppliers

Technological Properties

Weldability Flake Susceptibility
no limits not sensitive

Standards

Standard Description
GOST 2591-2006 GOST 2591-2006

Description of chemical elements

Element Units of measurement Description
Fe % Iron
Si % Silicon
Mn % Manganese
Cr % Chrome
Cu % Copper
Ni % Nickel
V % Vanadium
P % Phosphorus
C % Carbon
S % Sulfur
N % Nitrogen

Designation of types of weldability

Parameter Units of measurement Description
no limits Welding is performed without heating and without subsequent heat treatment
Boundedly welded Welding is possible with heating up to 100–120 °C and subsequent heat treatment
Difficult to weld For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing
Not applicable for welded structures