EJ2

Classification

Country Section Category
CIS, Russia, Ukraine Corrosion-resistant alloys and steels Corrosion-resistant alloys

Chemical composition

Standard Fe, % Si, % Mn, % Cr, % Ti, % Cu, % Ni, % V, % P, % C, % S, % Mo, % W, %
82.295–87.84 < 0.8 < 0.8 12–14 < 0.2 < 0.3 < 0.6 < 0.2 < 0.03 0.16–0.25 < 0.025 < 0.3 < 0.2

Note: For blade blanks with a lock thickness of more than 60 mm, a relative elongation of 1%, a relative narrowing of 5%, and a KCU of 9.8 J / cm2 are allowed

Note: OST 108.958.04-85: as agreed: S + P <0.035

Information on suppliers

Properties

Property
Tape according to GOST 4986 Soft tape Thickness: <0.2 mm; Tensile strength:> 490 MPa Elongation:> 8%
Tape according to GOST 4986 Soft tape Thickness: 0.2 - 2.0 mm; Tensile strength:> 490 MPa Elongation:> 16%
Sheet metal in accordance with GOST 5582 After softening heat treatment Temporary resistance:> 490 MPa Elongation:> 20%
Products according to GOST 5949 Note. The standards of mechanical properties apply to samples taken from steel with a diameter or thickness of up to 60 mm.
Products according to GOST 5949 Hardness HB: 126 - 197 Imprint diameter: 4.3 - 5.3 mm
Products according to GOST 5949 Option 1 Note Quenching from 1000-1050 ° С, cooling in air or in oil, tempering at 660-770 ° С, cooling in air, in oil or in water.
Products according to GOST 5949 Variant 1 Yield strength:> 440 MPa Tensile strength:> 650 MPa Elongation:> 16%
Products according to GOST 5949 Option 1 KCU impact strength at 20 ° C:> 78 J / cm2 Relative contraction:> 55%
Products according to GOST 5949 Option 2 Note Quenching from 1000-1050 ° С, cooling in air or in oil, tempering at 600-700 ° С, cooling in air, in oil or in water
Products according to GOST 5949 Variant 2 Yield strength:> 830 MPa Tensile strength:> 635 MPa Elongation:> 10%
Products according to GOST 5949 Option 2 Impact strength KCU at 20 ° C:> 59 J / cm2 Relative narrowing:> 50%
Plate rolling in accordance with GOST 7350 Yield strength:> 375 MPa Tensile strength:> 510 MPa Elongation:> 20%
Manufacturer's annealing Temporary resistance: <750 MPa
Wire according to GOST 18143 Heat-treated products Class 1 Diameter: 1 - 6 mm; Tensile strength: 540 - 780 MPa Elongation:> 20%
Wire according to GOST 18143 Heat-treated products Class 2 Diameter: 1 - 6 mm; Tensile strength: 540 - 780 MPa Elongation:> 14%
Wire according to GOST 18143 Cold drawn Diameter: 1 - 6 mm; Temporary resistance: 980 - 1320 MPa
Bars according to GOST 18907 Heat-treated products Heat-treated for a given strength (TP) Temporary resistance: 510 - 780 MPa Relative elongation:> 14%
Bars in accordance with GOST 18907 At the request of the consumer (optional) Diameter: 4 - 8 mm; Tensile strength: 666 - 784 MPa Elongation:> 16%
Bars in accordance with GOST 18907 At the request of the consumer (optional) Diameter:> 8 mm; Tensile strength:> 666 MPa Elongation: 16%
Bars in accordance with GOST 18907 Annealed (T) Diameter:> 5 mm; Hardness HB: 126 - 197 Imprint diameter: 4.3 - 5.3 mm
Products according to GOST 18968 Note When testing bars and strips with a diameter or thickness of 61-100 mm, elongation by 1% and narrowing by 5% of the absolute value is allowed,
as well as a decrease in impact strength by 5 J / cm2 at a rate of less than 78 J / cm2 and by 10 J / cm2 at a rate of 78 J / cm2 or more.
Products in accordance with GOST 18968 Note Bars and strips with a diameter of less than 16 mm and a thickness of less than 12 mm, made with full heat treatment,
instead of testing for relative narrowing and toughness, they perform a cold bend test of 180.
Products according to GOST 18968 Heat-treated samples Bars Diameter: <16 mm; Yield strength: 490 - 655 MPa Tensile strength:> 670 MPa Elongation:> 18%
Products according to GOST 18968 Heat-treated samples Bars Diameter: <16 mm; Hardness HB: 207 - 241 Diameter of a print: 3.9 - 4.2 mm
Products according to GOST 18968 Heat-treated samples Bars Diameter: 16 - 60 mm; Yield strength: 490 - 655 MPa Tensile strength:> 670 MPa Elongation:> 18% Hardness HB: 207 - 241
Products according to GOST 18968 Heat-treated samples Bars Diameter: 16 - 60 mm; KCU impact strength at 20 ° C:> 59 J / cm2 Relative narrowing:> 50% Imprint diameter: 3.9 - 4.2 mm
Products according to GOST 18968 Heat-treated samples Strips Thickness: <12 mm; Yield strength: 540 - 705 MPa Tensile strength:> 670 MPa Elongation:> 16%
Products according to GOST 18968 Heat-treated samples Strips Thickness: <12 mm; Hardness HB: 207 - 241 Diameter of a print: 3.9 - 4.2 mm
Products according to GOST 18968 Heat-treated samples Strips Thickness: 12 - 60 mm; Yield strength: 490 - 655 MPa Tensile strength:> 670 MPa Elongation:> 18% Hardness HB: 207 - 241
Products according to GOST 18968 Heat-treated samples Strips Thickness: 12 - 60 mm; KCU impact strength at 20 ° C:> 69 J / cm2 Relative narrowing:> 50% Imprint diameter: 3.9 - 4.2 mm
Products in accordance with GOST 19442 Note For bars with a thickness of more than 60 mm, a relative elongation of 1% is allowed.
Products in accordance with GOST 19442 Rods for connecting the blades Temporary resistance: 833 - 980 MPa Elongation:> 15% Hardness HB: 255 - 302
Products according to GOST 19442 Bars for connecting blades Strength category: KP70 Indent diameter: 3.5 - 3.8 mm
Products according to GOST 19442 Shaped rods Temporary resistance: 617 - 784 MPa Elongation:> 18% Hardness HB: 207 - 241
Products according to GOST 19442 Shaped rods Strength category: KP50 Imprint diameter: 3.9 - 4.2 mm
Products according to GOST 19442 Note With a rod thickness of more than 60 mm, a relative elongation of 1% and a relative contraction of 5% are allowed compared to those indicated in the table,
and impact strength of 4.9 J / cm2 at a rate of less than 78.4 J / cm2 and at 9.8 J / cm2 at a rate of 78.4 J / cm2 or more.
Products in accordance with GOST 19442 Bars for connecting blades Yield strength: 686 - 882 MPa Tensile strength:> 833 MPa Elongation:> 15% Hardness HB: 255 - 302
Products according to GOST 19442 Rods for blade connection Relative narrowing:> 50% Strength category: KP70 Imprint diameter: 3.5 - 3.8 mm
Products according to GOST 19442 Shaped rods Note Impact strength standards apply to rods with the largest profile thickness of 12 mm or more.
Bars with the largest profile thickness of less than 12 mm are subjected to bending tests.
Products according to GOST 19442 Shaped rods Yield strength: 490 - 656 MPa Tensile strength:> 666 MPa Elongation:> 18% Hardness HB: 207 - 241
Products according to GOST 19442 Shaped rods Impact strength KCU at 20 ° C:> 68.6 J / cm2 Relative narrowing:> 50% Strength category: KP50 Imprint diameter: 3.9 - 4.2 mm
Products according to GOST 25054 Note Mechanical properties of groups IV, IVK, V, VK and hardness of all groups except I.
Products according to GOST 25054 note the Mechanical properties of forgings, in addition to forging such as rings defines longitudinal samples after final heat treatment.
Products according to GOST 25054 Diameter: <200 mm; Yield strength:> 441 MPa Tensile strength:> 647 MPa Elongation:> 16% Hardness HB: 197 - 248
Products according to GOST 25054 Diameter: <200 mm; KCU impact strength at 20 ° C:> 6.5 J / cm2 Relative narrowing:> 50%
Products according to GOST 25054 Diameter: 200 - 500 mm; Yield strength:> 441 MPa Tensile strength:> 647 MPa Elongation:> 15% Hardness HB: 197 - 248
Products according to GOST 25054 Diameter: 200 - 500 mm Impact strength KCU at 20 ° C:> 5 J / cm2 Relative narrowing:> 45%
Products according to GOST 25054 Diameter: 500 - 1000 mm; Yield strength:> 441 MPa Tensile strength:> 647 MPa Elongation:> 14% Hardness HB: 197 - 248
Products according to GOST 25054 Diameter: 500 - 1000 mm; KCU impact strength at 20 ° C:> 4 J / cm2 Relative narrowing:> 40%
Blanks for turbine blades according to OST 108.020.03-82 Tempering with tempering Yield strength: 568 - 755 MPa Tensile strength:> 755 MPa Elongation:> 14%
Blanks for turbine blades according to OST 108.020.03-82 Tempering with tempering Hardness HB: 229 - 269 Impact strength KCU at 20 ° C:> 58 J / cm2 Relative narrowing:> 50%
Forgings according to OST 108.958.04-85 Strength category KP45 Longitudinal samples Thickness: <250 mm; Yield strength:> 440 MPa Tensile strength:> 635 MPa Elongation:> 14%
Forgings according to OST 108.958.04-85 Strength category KP45 Longitudinal samples Thickness: <250 mm; Hardness HB: 197 - 235 Impact strength KCU at 20 ° C:> 49 J / cm2 Relative narrowing:> 40%
Forgings according to OST 108.958.04-85 Longitudinal samples Thickness: <200 mm; Yield strength:> 490 MPa Tensile strength:> 655 MPa Elongation:> 13%
Forgings according to OST 108.958.04-85 Longitudinal samples Thickness: <200 mm; Hardness HB: 212 - 248 Impact strength KCU at 20 ° C:> 44 J / cm2 Relative narrowing:> 40%
Forgings according to OST 108.958.04-85 After heat treatment Thickness: <50 mm; HRCE Hardness: 30 - 34
Forgings according to OST 108.958.04-85 After heat treatment Thickness: 50 - 100 mm; Hardness HB: 248 - 293
Forgings according to OST 108.958.04-85 After heat treatment Thickness: 100 - 150 mm; Hardness HB: 235 - 277
Forgings according to OST 108.958.04-85 After heat treatment Thickness: 150 - 200 mm; Hardness HB: 223 - 262
Forgings according to OST 108.958.04-85 After heat treatment Thickness: 200 - 250 mm; Hardness HB: 212 - 248
Forgings according to OST 108.958.04-85 After heat treatment Thickness: 250 - 300 mm; Hardness HB: 197 - 235
Weldability By NAKS Group: M04 (W04)
Operational characteristics According to GOST R 54803-2011 Sheet Application temperature: -40 - 550 ° C
Operational characteristics According to GOST R 54803-2011 Forgings Application temperature: -40 - 550 ° C
Operational characteristics According to GOST R 54803-2011 According to the requirements of the Russian Maritime Register of Shipping Application temperature: -20 - 450 ° C Steel class: M-1
Operational characteristics According to GOST R 54803-2011 According to the requirements of the Russian Maritime Register of Shipping Application temperature: -20 - 450 ° C Steel class: M-1
Operational characteristics According to GOST R 54803-2011 According to ST TsKBA 025-2006 Application temperature: -40 - 450 ° C
Physical properties Density: 7.75 g / cm3
According to OST 5P.9125-84 Option 1 Note Yield Strength:> 441 MPa; Temporary Resistance:> 647 MPa; HB Hardness: 197 - 229
According to OST 5P.9125-84 By thickness Note Continuous section: diameter (thickness) Hollow section: wall thickness
According to OST 5P.9125-84 Thickness Diameter or thickness: <60 mm; Wall thickness: <50 mm; Elongation:> 16% Impact strength KCU at 20 ° C:> 80 J / cm2 Elongation:> 55%
According to OST 5P.9125-84 Thickness Diameter or thickness: 60 - 100 mm; Wall thickness: 50 - 80 mm; Relative elongation:> 15% Impact strength KCU at 20 ° C:> 75 J / cm2 Relative narrowing:> 50%
According to OST 5P.9125-84 Thickness Diameter or thickness: 100 - 300 mm; Wall thickness: 80 - 210 mm; Relative elongation:> 13% Impact strength KCU at 20 ° C:> 50 J / cm2 Relative narrowing:> 45%
According to OST 5P.9125-84 Option 2 Note Quenching 1000 -1050 ° С in oil Holidays 630 - 650 ° С, air
According to OST 5P.9125-84 Option 2 Yield strength:> 540 MPa Tensile strength:> 687 MPa Hardness HB: 217 - 269
According to OST 5P.9125-84 Option 2 According to OST 5P.9125-84 Option 2
According to OST 5P.9125-84 Option 2 Diameter or thickness: <60 mm; Wall thickness: <50 mm; Elongation:> 15% Impact strength KCU at 20 ° C:> 60 J / cm2 Elongation:> 50%
According to OST 5P.9125-84 Option 2 Diameter or thickness: 60 - 100 mm; Wall thickness: 50 - 80 mm; Elongation:> 14% Impact strength KCU at 20 ° C:> 55 J / cm2 Elongation:> 45%
According to OST 5P.9125-84 Option 2 Diameter or thickness: 100 - 300 mm; Wall thickness: 80 - 210 mm; Elongation:> 12% Impact strength KCU at 20 ° C:> 40 J / cm2 Elongation:> 40%

Analogues

Germany USA
1.4014 K91151

Description of chemical elements

Element Units of measurement Description
Fe % Iron
Si % Silicon
Mn % Manganese
Cr % Chrome
Ti % Titan
Cu % Copper
Ni % Nickel
V % Vanadium
P % Phosphorus
C % Carbon
S % Sulfur
Mo % Molybdenum
W % Tungsten