Titanium alloy 19B
No foreign analogues
It is used for the production of products operating for a long time at temperatures up to 500 °
No foreign analogues
It is used for the production of products operating for a long time at temperatures up to 500 °
Standard | Fe, % | Si, % | B, % | Ti, % | Zr, % | Al, % | C, % | O, % | Nb, % | N, % | H, % | ET, % |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Standard | Fe, % | Si, % | B, % | Ti, % | Zr, % | Al, % | C, % | O, % | Nb, % | N, % | H, % | ET, % |
GOST 19807-91 | < 0.2 | < 0.12 | < 0.003 | 86.111–91.5 | 1–2.5 | 5–6.5 | < 0.08 | < 0.14 | 2.5–4 | < 0.04 | < 0.006 | < 0.3 |
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{Y}, MPa | d5, % | Treatment |
---|---|---|---|---|---|---|---|---|
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{Y}, MPa | d5, % | Treatment |
Rod | GOST 26492-85 | 40 | raw, compacting, fat, Transverse | 1000–1150 | 800–850 | 10–14 |
Rolling | Standard | Classifiers | Value, HBW |
---|---|---|---|
Rolling | Standard | Classifiers | Value, HBW |
Rod | GOST 26492-85 | 280–330 |
Standard | Description |
---|---|
Standard | Description |
GOST 19807-91 | |
OST 1-92077-91 | OST |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
E\cdot 10^{9} | MPa | Elastic modulus |
\alpha\cdot 10^{6} | K^{-1} | Coefficient of thermal (linear) expansion (range 20°C–T) |
\varkappa | \frac{W}{m\cdot K} | Coefficient of thermal conductivity (the heat capacity of the material) |
\rho | \frac{kg}{m^3} | The density of the material |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |