03H21N21M4GB (ZI35, 00Х20Н20М4Б)

St. equipment of phosphoric phosphoric to-you, mineral fertilizers, cellulose acetate, vinyl acetate, and other aggressive media and with intensive wear — mixers, separators, extractors. 8000kg / m3. OZL-17U, OZL-26A, EA-395/9.

for welded structures and components operating in conditions of hot phosphoric acid doped with fluorine and sulfur compounds, as well as a low concentration of sulfuric acid at temperatures up to 80 degrees C, with nitric acid at temperatures up to 95 degrees C; austenitic steel

Classification

Country Section Category
CIS, Russia, Ukraine Corrosion-resistant alloys and steels Corrosion-resistant ordinary steel

Chemical composition

Standard Fe, % Si, % Mn, % Cr, % Ni, % P, % C, % S, % Mo, %
GOST 5632-72 49.12–54.8 < 0.6 1.8–2.5 20–22 20–22 < 0.03 < 0.03 < 0.02 3.4–3.7

Information on suppliers

Mechanical properties at 20 °C

Rolling Standard Size, mm Tension Classifiers $$\sigma _{U}$$, $$MPa$$ $$\sigma_{P}$$, $$MPa$$ $$\epsilon_L$$, % Treatment
Forgings GOST 25054-81 < 600 Longitudinal 490 215
The plates GOST 7350-77 590 295 30 Hardening of 1060-1120 ° C, cooling water
Sheet GOST 5582-75 540 245 25 Hardening of 1080-1130 ° C, the water

Technological Properties

Weldability
no limits

Standards

Description of chemical elements

Element Units of measurement Description
Fe % Iron
Si % Silicon
Mn % Manganese
Cr % Chrome
Ni % Nickel
P % Phosphorus
C % Carbon
S % Sulfur
Mo % Molybdenum

Description of mechanical properties

Parameter Units of measurement Description
$$\sigma _{U}$$ $$MPa$$ Ultimate tensile strength
$$\sigma_{P}$$ $$MPa$$ Proportionality limit
$$\epsilon_L$$ % Elongation at break (longitudinal)

Designation of types of weldability

Parameter Units of measurement Description
no limits Welding is performed without heating and without subsequent heat treatment
Boundedly welded Welding is possible with heating up to 100–120 °C and subsequent heat treatment
Difficult to weld For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing
Not applicable for welded structures