08H15N24V4TR (EP164, X15H24V4T)
Work and guide vanes, fasteners, gas turbine disks.
working and guide blades, fasteners, drives a gas turbine with a long service life at a temperature of 650−700 degrees.; austenitic steel
Work and guide vanes, fasteners, gas turbine disks.
working and guide blades, fasteners, drives a gas turbine with a long service life at a temperature of 650−700 degrees.; austenitic steel
Standard | Fe, % | Si, % | B, % | Mn, % | Cr, % | Ti, % | Ni, % | Ce, % | P, % | C, % | S, % | W, % |
---|---|---|---|---|---|---|---|---|---|---|---|---|
GOST 5632-72 | 50.435–58.1 | < 0.6 | < 0.005 | 0.5–1 | 14–16 | 1.4–1.8 | 22–25 | < 0.025 | < 0.035 | < 0.08 | < 0.02 | 4–5 |
Standard | Description |
---|---|
GOST 5632-72 | |
TU 14-1-1139-74 |
Parameter | Units of measurement | Description |
---|---|---|
$$E\cdot 10^{9}$$ | $$MPa$$ | Elastic modulus |
$$\alpha\cdot 10^{6}$$ | $$K^{-1}$$ | Coefficient of thermal (linear) expansion (range 20°C–T) |
$$\varkappa$$ | $$\frac{W}{m\cdot K}$$ | Coefficient of thermal conductivity (the heat capacity of the material) |
$$\rho$$ | $$\frac{kg}{m^3}$$ | The density of the material |
Parameter | Units of measurement | Description |
---|---|---|
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |