EP979 (Sv-03XH25MDG)
Classification
Chemical composition
Standard | Fe, % | Si, % | Mn, % | Cr, % | Ti, % | Cu, % | Ni, % | P, % | C, % | S, % | Nb, % | Mo, % |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Standard | Fe, % | Si, % | Mn, % | Cr, % | Ti, % | Cu, % | Ni, % | P, % | C, % | S, % | Nb, % | Mo, % |
TU 14-1-2571-78 | 38.487–47 | < 0.25 | 1.5–2.5 | 22–25 | < 0.1 | 2.5–3.5 | 24.5–27 | < 0.02 | < 0.025 | < 0.018 | < 0.1 | 2.5–3 |
Information on suppliers
Physical characteristics
Mechanical properties at 20 °C
Rolling | Standard | Size, mm | Tension | Classifiers | $$\sigma _{U}$$, $$MPa$$ | $$\sigma_{Y}$$, $$MPa$$ | d5, % | Treatment |
---|---|---|---|---|---|---|---|---|
Rolling | Standard | Size, mm | Tension | Classifiers | $$\sigma _{U}$$, $$MPa$$ | $$\sigma_{Y}$$, $$MPa$$ | d5, % | Treatment |
Wire | GOST 5632-14 | 10 | Transverse | raw, cold drawn, thin, Transverse | 980–1050 | 480–540 | 35–40 |
Brinell hardness number
Rolling | Standard | Classifiers | Value, HBW |
---|---|---|---|
Rolling | Standard | Classifiers | Value, HBW |
Wire | GOST 5632-14 | raw, cold drawn, thin, Transverse | 200–220 |
Technological Properties
Standards
Standard | Description |
---|---|
Standard | Description |
TU 14-1-2571-78 |
Description of chemical elements
Description of physical characteristics
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
Cp | Дж/кг·К | Specific heat of material |
$$E\cdot 10^{9}$$ | $$MPa$$ | Elastic modulus |
$$\varkappa$$ | $$\frac{W}{m\cdot K}$$ | Coefficient of thermal conductivity (the heat capacity of the material) |
$$R\cdot 10^{-6}$$ | $$\Omega\cdot m$$ | Electrical resistivity |
Description of mechanical properties
Designation of types of weldability
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |