EP616A Nickel Alloy (НХ26С2Р2)
Designed for the manufacture of precision instruments, thermocouples and compensation wires
Classification
| Country |
Section |
Category |
| CIS, Russia, Ukraine |
Heat resistant steels and alloys |
Heat resistant alloys |
Chemical composition
| Standard |
Fe, % |
Si, % |
B, % |
Mn, % |
Cu, % |
Ni, % |
Al, % |
| GOST 492-2006 |
< 3 |
1.8–2.3 |
1.2–1.8 |
< 0.4 |
< 0.25 |
92.21–97 |
< 0.04 |
Information on suppliers
Physical characteristics
| Temperature, °C |
$$\varkappa$$, $$\frac{W}{m\cdot K}$$ |
$$\rho$$, $$\frac{kg}{m^3}$$ |
Cp, Дж/кг·К |
| 20 |
55.5–62.5 |
8000 |
456 |
Mechanical properties at 20 °C
| Rolling |
Standard |
Size, mm |
Tension |
Classifiers |
$$\sigma _{U}$$, $$MPa$$ |
$$\sigma_{0.2}$$, $$MPa$$ |
d5, % |
Treatment |
| Tape |
GOST 5632-14 |
1 |
Transverse |
raw, cold rolling, thin, Transverse |
680–720 |
390–420 |
5–9 |
|
Твёрдость по Роквеллу
| Rolling |
Standard |
Classifiers |
Value, HRC |
| Tape |
GOST 5632-14 |
raw, cold rolling, thin, Transverse |
37–40 |
Technological Properties
| Weldability |
Flake Susceptibility |
Propensity to temper brittleness |
| no limits |
not sensitive |
loathsome |
Limit operating modes
Long-term strength
| Standard |
Treatment |
Постоянно приложенное напряжение, МПа |
| GOST 5632-14 |
|
> 190 |
Standards
Description of chemical elements
| Element |
Units of measurement |
Description |
| Fe |
% |
Iron |
| Si |
% |
Silicon |
| B |
% |
Bor |
| Mn |
% |
Manganese |
| Cu |
% |
Copper |
| Ni |
% |
Nickel |
| Al |
% |
Aluminium |
Description of physical characteristics
| Parameter |
Units of measurement |
Description |
| Cp |
Дж/кг·К |
Specific heat of material |
| $$\varkappa$$ |
$$\frac{W}{m\cdot K}$$ |
Coefficient of thermal conductivity (the heat capacity of the material) |
| $$\rho$$ |
$$\frac{kg}{m^3}$$ |
The density of the material |
Description of mechanical properties
| Parameter |
Units of measurement |
Description |
| d5 |
% |
Elongation at break |
| $$\sigma_{0.2}$$ |
$$MPa$$ |
Tensile stress required to produce a total elongation of 0.2% |
| $$\sigma _{U}$$ |
$$MPa$$ |
Ultimate tensile strength |
Designation of types of weldability
| Parameter |
Units of measurement |
Description |
| no limits |
|
Welding is performed without heating and without subsequent heat treatment |
| Boundedly welded |
|
Welding is possible with heating up to 100–120 °C and subsequent heat treatment |
| Difficult to weld |
|
For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing |
| Not applicable for welded structures |
|
|