HN75MBTYU (EI602)
Details of gas pipeline systems, equipment.
details of pipeline systems, hardware, parts of the combustion chambers with a limited service life at temperatures up to 950 degrees C; heat-resisting alloy
Details of gas pipeline systems, equipment.
details of pipeline systems, hardware, parts of the combustion chambers with a limited service life at temperatures up to 950 degrees C; heat-resisting alloy
Standard | Fe, % | Si, % | Mn, % | Cr, % | Ti, % | Ni, % | Al, % | P, % | C, % | S, % | Nb, % | Mo, % |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Standard | Fe, % | Si, % | Mn, % | Cr, % | Ti, % | Ni, % | Al, % | P, % | C, % | S, % | Nb, % | Mo, % |
GOST 5632-72 | < 3 | < 0.8 | < 0.4 | 19–22 | 0.35–0.75 | 68.568–77.6 | 0.35–0.75 | < 0.02 | < 0.1 | < 0.012 | 0.9–1.3 | 1.8–2.3 |
Temperature, °C | E\cdot 10^{9}, MPa | \alpha\cdot 10^{6}, K^{-1} | \varkappa, \frac{W}{m\cdot K} | \rho, \frac{kg}{m^3} |
---|---|---|---|---|
Temperature, °C | E\cdot 10^{9}, MPa | \alpha\cdot 10^{6}, K^{-1} | \varkappa, \frac{W}{m\cdot K} | \rho, \frac{kg}{m^3} |
20 | 190 | 8300 | ||
100 | 12.4 | 13.45 | ||
200 | 13.4 | 15.3 | ||
300 | 14.2 | 16.7 | ||
400 | 165 | 15 | 18.5 | |
500 | 163 | 15.8 | 20.2 | |
600 | 150 | 16.5 | 22.3 | |
700 | 137 | 18.1 | 24.4 |
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{P}, MPa | \epsilon_L, % | \psi, % | Treatment |
---|---|---|---|---|---|---|---|---|---|
Rolling | Standard | Size, mm | Tension | Classifiers | \sigma _{U}, MPa | \sigma_{P}, MPa | \epsilon_L, % | \psi, % | Treatment |
Sheet | GOST 24982-81 | 900–930 | 40 | Hardening of 1050-1080 ° C | |||||
Castings | GOST 7769-82 | 860 | 400 | 43 | 37 | Hardening of 1050-1080 ° C, air |
Standard | Description |
---|---|
Standard | Description |
GOST 5632-72 | |
TU 14-1-3721-84 | |
GOST 24982-81 | |
GOST 5632-14 | |
TU 14-1-1531-76 | |
TU 14-1-1747-76 | |
TU 14-1-4296-87 | |
TU 14-143-476-95 |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
E\cdot 10^{9} | MPa | Elastic modulus |
\alpha\cdot 10^{6} | K^{-1} | Coefficient of thermal (linear) expansion (range 20°C–T) |
\varkappa | \frac{W}{m\cdot K} | Coefficient of thermal conductivity (the heat capacity of the material) |
\rho | \frac{kg}{m^3} | The density of the material |
Parameter | Units of measurement | Description |
---|---|---|
Parameter | Units of measurement | Description |
no limits | Welding is performed without heating and without subsequent heat treatment | |
Boundedly welded | Welding is possible with heating up to 100–120 °C and subsequent heat treatment | |
Difficult to weld | For obtaining quality welded joints, additional operations are required: heating up to 200–300 °C for welding, heat treatment after welding — annealing | |
Not applicable for welded structures |